Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

  1. Receives the protocol setting and analog/digital channel settings.
  2. Creates analog channel object handle to read the amount of hand gripe force from BIOPAC acquisition unit.
  3. Creates digital channel object handle to read the 0-7 button press event.
  4. Creates figure on the extended screen with given coordinates.
  5. Creates axes, level indication bar that indicates to the amount of hand grip force.
  6. Creates labels "MAX Force1=","MAX Force2=","MAX Force3=" indicating maximum acquired value of hand grip force during measurement-1, measurement-2, measurement-3 respectively.
  7. Creates indicator in the upper right corner indicating the currently ongoing measurement number.
  8. Extracts the calibration parameters from received channel settings object.
  9. Outputs the analog signal to BIOPAC protocol channel, with voltage level corresponding to "Hand Grip MAX" protocol.

Acquisition

 In this phase function physRunHandgripMax looks for the maximum value of hang grip that has been acquired during n-th measurement. As subject applies a force the program monitors and stores the maximum value that have been acquired in variable HANDMAX_TMP(n), which is displayed in real time on the screen. Subject can continue applying force but new value will be accepted only if it is greater than previously recorded force value during the same measurement. To proceed to next measurement any of 0-7 buttons shall be pressed.