Here's a way to test ASL scans (snapshots for each step on right):
- Convert images with CSPM
- Check for multiple nifti images; should have a minimum of 2, usually more
- Run a global timetrend; from CSPM fMRI menu, select Global Timetrend, select the images, and choose Raw
- Check that the images are high/low or low/high (unlabeled/labelled or labeled/unlabeled)
- Create CBF maps from ASL menu; select the images, and ignore the mask (click "Done" with nothing selected
- Review the mean CBF image; if the values are negative, the order is flipped. If the values are super high or super low, the default parameters are off; However, the relative intensities won't change with the correct parameters, only the scaling.
- To change settings, edit the cspm_asl.m file - click the link in the command window to open.