In the GUI, set these then "Run" to re-calculate peaks. This will overwrite any manual peak editing you did.

GUI ParameterCommand Line ParameterMeaningChange
Moving avg. window (secs.)mawindowwindow length for moving averagereduce to allow for faster baseline trend changes
Threshold decay time constant Pkdecaytimeconstpk decay time constant for peaksreduce to detect more peaks; this determines how fast the peak threshold decays down from the previous peak towards.
Threshold decay time constant Trdecaytimeconsttrdecay time constant for troughsreduce to detect more troughs; this determines how fast the peak threshold decays up from the previous trough.
Threshold limit (%last peaks/troughs) Pkthreshlimpk percent of peak height above moving average mean (sets lower bound for peak decay)decrease to detect more peaks (can be negative)
Threshold limit (%last peaks/troughs) Trthreshlimtrpercent of trough depth below moving average mean (sets upper bound for trough decay)decrease to detect more peaks (can be negative)
Min. interval (checkbox)flagmininterval flag for using/not using mininternvalset to 0 for not using (useful if you want to have a flags structure to test, but don't want to constantly change or remove "mininterval")
Min. interval (text box)mininterval minimum interval allowed between peaks (or troughts)set so that no non-physiologic values are found (e.g. in seconds, 0.25 ~ 4 Hz ~ 240 bpm)

...