See FSL website for analysis details.

Preparing T1 files

FSL does not read all nifti files properly, so we convert them. There was some issue with reading rotations/shears, so these are removed with reslicing. Additionally, testing on 0.65 x 0.65 x 0.0.65 mm voxel size files also needed a conversion to int16 from float 32 data format.

Manually Running and Testing

OLD: To set up FSL FIRST to run custom VOI:

(Paul worked with Brian from FSL for a few months trying to be able to use custom VOI's, but FIRST had a major upgrade which superceeded all the changes (which never worked properly anyway).)

- Copy the file from Windows to the LinuxShare folder
- In Linux, open a file browser and go to /usr/local/fsl/bin
- Rename the old "first" executable file "first_old"
- In Linux, copy the new file to the folder Document Iconfirst

- Copy the file from Windows to the LinuxShare folder
- In Linux, open a file browser and go to /usr/local/fsl/bin
- Rename the old "first" executable file "first_old"
- Copy the new file to the /usr/loca/fsl/bin folder Document Iconrun_first_dev
- In Linux, open a terminal and run the following commands, to remove extra carraige return characters that Windows puts in text files:
[...]$ cd /usr/local/fsl/bin
[...]$ dos2unix run_first_dev